{"id":5131,"date":"2026-11-28T11:24:36","date_gmt":"2026-11-28T11:24:36","guid":{"rendered":"https:\/\/estrexsolar.co.ke\/?post_type=product&#038;p=5131"},"modified":"2026-11-28T11:30:33","modified_gmt":"2026-11-28T11:30:33","slug":"chint-nxb-series-mcb-4-pole","status":"publish","type":"product","link":"https:\/\/estrexsolar.co.ke\/?product=chint-nxb-series-mcb-4-pole","title":{"rendered":"CHINT NXB Series MCB 4 Pole"},"content":{"rendered":"<div class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAA\" data-complete=\"true\" data-processed=\"true\">The CHINT NXB Series MCB 4 Pole<strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\"> (Miniature Circuit Breaker)<!--TgQPHd|||[]--><\/strong> <mark class=\"b6AQX\" data-wiz-attrbind=\"class=L38Wqc_2h\/cFwyDc\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjclYC5xKqYAxV8k_0HHRhvKacQuJAPeggIAggBCBIQAQ\" data-complete=\"true\" data-sae=\"\">provides three-phase overload protection, short-circuit protection, and positive isolation for low-voltage AC systems up to <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">400V\/415V<!--TgQPHd|||[]--><\/strong><!--TgQPHd|||[[[null,null,null,null,null,null,null,null,null,null,null,null,[247864,null,0]]]]--><\/mark>. The lineup spans frame sizes from <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\">1A to 125A<!--TgQPHd|||[]--><\/strong> across four main sub-models tailored to different breaking capacities and application standards. <!--TgQPHd|||[[1,null,[null,null,1,1,null,null,null,null,null,null,null,null,[268154,null,0],null,null,[{&quot;1285&quot;:[1]}]],0,null,null,null,[null,null,4,null,7,null,null,6,10,7],null,null,1]]--><\/div>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div role=\"heading\" aria-level=\"4\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=L38Wqc_4e\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAA\" data-complete=\"true\" data-sae=\"\"><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"4\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=L38Wqc_4e\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAA\" data-complete=\"true\" data-sae=\"\">CHINT NXB Series MCB 4 Pole Shared Technical Specifications<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAA\" data-complete=\"true\" data-processed=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAI\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Electrical Ratings.<!--TgQPHd|||[]--><\/strong> Operates on <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">50\/60Hz<!--TgQPHd|||[]--><\/strong> AC networks at <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">380V\/400V\/415V<!--TgQPHd|||[]--><\/strong> for 4-pole configurations. Rated insulation voltage ((U_{i})) is <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">500V<!--TgQPHd|||[]--><\/strong>, and rated impulse withstand voltage ((U_{imp})) is <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">4kV<!--TgQPHd|||[]--><\/strong>.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAk\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Tripping Characteristics.<!--TgQPHd|||[]--><\/strong> Available in <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">B curve<!--TgQPHd|||[]--><\/strong> (3\u20135(I_{n})) for resistive loads, <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">C curve<!--TgQPHd|||[]--><\/strong> (5\u201310(I_{n})) for general commercial and inductive circuits, and <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">D curve<!--TgQPHd|||[]--><\/strong> (10\u201314(I_{n})) for high-inrush motors and transformers.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEBE\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Durability &amp; Environment.<!--TgQPHd|||[]--><\/strong> Rated for <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">20,000 mechanical cycles<!--TgQPHd|||[]--><\/strong> and <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">6,000 to 10,000 electrical cycles<!--TgQPHd|||[]--><\/strong> depending on current frame. Functions reliably in ambient temperatures from <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">\u201335\u00b0C to +70\u00b0C<!--TgQPHd|||[]--><\/strong> at altitudes up to <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">2,000m<!--TgQPHd|||[]--><\/strong>.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEBY\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Mounting &amp; Wiring.<!--TgQPHd|||[]--><\/strong> Snaps onto a standard <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">35mm DIN rail (TH35-7.5)<!--TgQPHd|||[]--><\/strong> and accepts copper conductors. Terminal tightening torque is <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">2.0 N\u00b7m<!--TgQPHd|||[]--><\/strong> for NXB-63 frames and <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">3.5 N\u00b7m<!--TgQPHd|||[]--><\/strong> for NXB-80 frames.<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The CHINT NXB Series MCB 4 Pole (Miniature Circuit Breaker) provides three-phase overload protection, short-circuit protection, and positive isolation for low-voltage AC systems up to 400V\/415V. The lineup spans frame sizes from 1A to 125A across four main sub-models tailored to different breaking capacities and application standards. CHINT NXB Series MCB 4 Pole Shared Technical [&#8230;]\n","protected":false},"featured_media":5136,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[163],"product_cat":[129],"product_tag":[],"class_list":["post-5131","product","type-product","status-publish","has-post-thumbnail","product_brand-chint","product_cat-mcb","first","instock","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product\/5131","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5131"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/media\/5136"}],"wp:attachment":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5131"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=5131"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=5131"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=5131"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}