{"id":5110,"date":"2026-11-28T10:55:36","date_gmt":"2026-11-28T10:55:36","guid":{"rendered":"https:\/\/estrexsolar.co.ke\/?post_type=product&#038;p=5110"},"modified":"2026-11-28T11:12:24","modified_gmt":"2026-11-28T11:12:24","slug":"chint-nxb-series-mcb-2-pole","status":"publish","type":"product","link":"https:\/\/estrexsolar.co.ke\/?product=chint-nxb-series-mcb-2-pole","title":{"rendered":"CHINT NXB series MCB 2 Pole"},"content":{"rendered":"<div class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgJEAA\" data-complete=\"true\" data-processed=\"true\"><span data-subtree=\"aimfl\" data-processed=\"true\">The CHINT NXB series MCB 2 Pole<\/span>\u00a0are <mark class=\"b6AQX\" data-wiz-attrbind=\"class=MH8ETd_q\/cFwyDc\" data-sfc-root=\"c\" data-ved=\"2ahUKEwi53uy3wKqYAxUwnv0HHV9PJXoQuJAPeggIAggBCAkQAQ\" data-complete=\"true\" data-sae=\"\">DIN-rail mounted protective devices designed for overload and short-circuit protection in single-phase (Live + Neutral) or two-phase AC circuits<!--TgQPHd|||[[[null,null,null,null,null,null,null,null,null,null,null,null,[247864,null,0]]]]--><\/mark>. They comply with <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\">IEC\/EN 60898-1<!--TgQPHd|||[]--><\/strong> (for domestic\/commercial use) and <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\">IEC\/EN 60947-2<!--TgQPHd|||[]--><\/strong> (for higher current industrial applications).<!--TgQPHd|||[]--><\/div>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"4\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=MH8ETd_12\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAA\" data-complete=\"true\" data-sae=\"\">Sub-Models in the 2-Pole NXB Range<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"4\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=MH8ETd_33\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgWEAA\" data-complete=\"true\" data-sae=\"\">CHINT NXB series MCB 2 Pole Key Technical Specifications\u00a0<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAA\" data-processed=\"true\" data-complete=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAI\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Rated Operational Voltage (\\(U_{e}\\)).<!--TgQPHd|||[]--><\/strong> 230V\/240V AC or 380V\/400V\/415V AC at 50\/60Hz.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAg\" data-sae=\"\" data-complete=\"true\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Insulation &amp; Impulse Withstand.<!--TgQPHd|||[]--><\/strong> Rated insulation voltage (\\(U_{i}\\)) of 500V and impulse withstand voltage (\\(U_{imp}\\)) of 4kV.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEA8\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Tripping Characteristics.<!--TgQPHd|||[]--><\/strong><!--TgQPHd|||[]--><\/span>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEBA\" data-complete=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEBE\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">B-Curve (3\u20135 \\(I_{n}\\)).<!--TgQPHd|||[]--><\/strong> Suitable for resistive loads, lighting, and long cable runs.<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEBM\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">C-Curve (5\u201310 \\(I_{n}\\)).<!--TgQPHd|||[]--><\/strong> Standard for general power, mixed loads, and small inductive devices.<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEBU\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">D-Curve (10\u201320 \\(I_{n}\\)).<!--TgQPHd|||[]--><\/strong> Designed for high inrush currents such as motors and transformers.<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><\/li>\n<p><!--TgQPHd|||[]--><\/ul>\n<p><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEBk\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Service Lifespan.<!--TgQPHd|||[]--><\/strong> Up to 20,000 mechanical cycles and 10,000 electrical cycles (up to 63A).<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEB4\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Physical &amp; Mounting.<!--TgQPHd|||[]--><\/strong> Standard 35mm DIN rail (TH35-7.5) installation. A 2-pole unit occupies 2 DIN modules (approx. 36mm width) and features a green\/red contact position indicator window.<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The CHINT NXB series MCB 2 Pole\u00a0are DIN-rail mounted protective devices designed for overload and short-circuit protection in single-phase (Live + Neutral) or two-phase AC circuits. They comply with IEC\/EN 60898-1 (for domestic\/commercial use) and IEC\/EN 60947-2 (for higher current industrial applications). Sub-Models in the 2-Pole NXB Range CHINT NXB series MCB 2 Pole Key [&#8230;]\n","protected":false},"featured_media":5118,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[163],"product_cat":[129],"product_tag":[],"class_list":["post-5110","product","type-product","status-publish","has-post-thumbnail","product_brand-chint","product_cat-mcb","first","instock","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product\/5110","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5110"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/media\/5118"}],"wp:attachment":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5110"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=5110"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=5110"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=5110"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}