{"id":5073,"date":"2026-11-28T08:56:47","date_gmt":"2026-11-28T08:56:47","guid":{"rendered":"https:\/\/estrexsolar.co.ke\/?post_type=product&#038;p=5073"},"modified":"2026-11-28T08:56:48","modified_gmt":"2026-11-28T08:56:48","slug":"chint-np72-v-analog-panel-voltmeter","status":"publish","type":"product","link":"https:\/\/estrexsolar.co.ke\/?product=chint-np72-v-analog-panel-voltmeter","title":{"rendered":"Chint NP72-V Analog Panel Voltmeter"},"content":{"rendered":"<div class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAA\" data-complete=\"true\" data-processed=\"true\"><span data-subtree=\"aimfl\" data-processed=\"true\">The Chint NP72-V Analog Panel Voltmeter<\/span>\u00a0is a <mark class=\"b6AQX\" data-wiz-attrbind=\"class=weO7K_s\/cFwyDc\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjr1MPwo6qYAxVipf0HHbQvNpwQuJAPeggIAggBCA0QAQ\" data-complete=\"true\" data-sae=\"\">72 \u00d7 72 mm direct-acting square analog panel voltmeter designed for monitoring AC voltage levels in electrical distribution boards and control panels<!--TgQPHd|||[[[null,null,null,null,null,null,null,null,null,null,null,null,[247864,null,0]]]]--><\/mark>. It features a flame-retardant ABS casing, a printed dial scale with a transparent glass cover, and a pointer needle for reading voltage trends at a glance.\u00a0<!--TgQPHd|||[]--><\/div>\n<div data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgNEAA\" data-complete=\"true\" data-processed=\"true\"><\/div>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"4\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=weO7K_11\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAA\" data-complete=\"true\" data-sae=\"\">Chint NP72-V Analog Panel Voltmeter Technical Specifications<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAA\" data-processed=\"true\" data-complete=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAI\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Front Bezel Dimensions.<!--TgQPHd|||[]--><\/strong> The outer bezel measures <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">72 \u00d7 72 mm<!--TgQPHd|||[]--><\/strong>, with a mounting depth of <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">67.5 mm<!--TgQPHd|||[]--><\/strong> behind the panel.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAc\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Panel Cutout Size.<!--TgQPHd|||[]--><\/strong> The required square mounting hole is <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">68 \u00d7 68 mm<!--TgQPHd|||[]--><\/strong>.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAw\" data-sae=\"\" data-complete=\"true\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Common Voltage Scales.<!--TgQPHd|||[]--><\/strong> Standard direct-connection AC models (<code class=\"KDcb0c\" dir=\"ltr\" data-sfc-root=\"c\" data-complete=\"true\" data-sae=\"\">NP72-V<!--TgQPHd|||[]--><\/code>) are rated for <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">0\u2013300V AC<!--TgQPHd|||[]--><\/strong> (single-phase) and <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">0\u2013500V AC<!--TgQPHd|||[]--><\/strong> (three-phase), with custom AC and DC (<code class=\"KDcb0c\" dir=\"ltr\" data-sfc-root=\"c\" data-complete=\"true\">NP72-DC<!--TgQPHd|||[]--><\/code>) ranges available.<\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEBE\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Accuracy Class.<!--TgQPHd|||[]--><\/strong> Rated at <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Class 1.5<!--TgQPHd|||[]--><\/strong> under IEC\/EN 60051 standards.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEBY\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Operating Environment.<!--TgQPHd|||[]--><\/strong> Rated for vertical panel mounting at 50\/60 Hz across ambient temperatures from <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">-20\u00b0C to +70\u00b0C<!--TgQPHd|||[]--><\/strong>, with a 2 kV dielectric insulation rating.<\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<p><!--TgQPHd|||[]--><\/ul>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"4\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=weO7K_2s\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAA\" data-complete=\"true\" data-sae=\"\">Chint NP72-V Analog Panel Voltmeter Wiring &amp; Installation Notes<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAA\" data-processed=\"true\" data-complete=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAI\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Direct Connection.<!--TgQPHd|||[]--><\/strong> Standard scales up to 500V AC wire directly across the phase and neutral (for 300V meters) or phase-to-phase (for 500V meters) without needing a potential transformer.<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAM\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Three-Phase Monitoring.<!--TgQPHd|||[]--><\/strong> In three-phase panels, a single <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">NP72-V 0\u2013500V<!--TgQPHd|||[]--><\/strong> meter is typically paired with a rotary voltmeter selector switch to read all three line-to-line (L1-L2, L2-L3, L3-L1) and line-to-neutral voltages.<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgZEAQ\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Circuit Protection.<!--TgQPHd|||[]--><\/strong> Install a low-amp control fuse or miniature circuit breaker (such as a 2A or 6A MCB) on the voltage sensing lines to protect the meter and panel wiring against short circuits.<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The Chint NP72-V Analog Panel Voltmeter\u00a0is a 72 \u00d7 72 mm direct-acting square analog panel voltmeter designed for monitoring AC voltage levels in electrical distribution boards and control panels. It features a flame-retardant ABS casing, a printed dial scale with a transparent glass cover, and a pointer needle for reading voltage trends at a glance.\u00a0 [&#8230;]\n","protected":false},"featured_media":5074,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[163],"product_cat":[132],"product_tag":[],"class_list":["post-5073","product","type-product","status-publish","has-post-thumbnail","product_brand-chint","product_cat-energy-meter","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product\/5073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5073"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/media\/5074"}],"wp:attachment":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5073"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=5073"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=5073"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=5073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}