{"id":4327,"date":"2026-10-26T09:25:26","date_gmt":"2026-10-26T09:25:26","guid":{"rendered":"https:\/\/estrexsolar.co.ke\/?post_type=product&#038;p=4327"},"modified":"2026-10-31T08:36:36","modified_gmt":"2026-10-31T08:36:36","slug":"suntree-solar-pv-dc-fuse-link-with-holder-1p-1000vdc","status":"publish","type":"product","link":"https:\/\/estrexsolar.co.ke\/?product=suntree-solar-pv-dc-fuse-link-with-holder-1p-1000vdc","title":{"rendered":"Suntree Solar PV DC Fuse Link with Holder 1P 1000Vdc"},"content":{"rendered":"<div class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgKEAA\" data-complete=\"true\" data-processed=\"true\"><span data-subtree=\"aimfl\" data-processed=\"true\">The Suntree Solar PV DC Fuse Link with Holder 1P 1000Vdc<\/span>\u00a0is <mark class=\"b6AQX\" data-wiz-attrbind=\"class=UwQXMe_t\/cFwyDc\" data-sfc-root=\"c\" data-ved=\"2ahUKEwjLyc3a6-OXAxUI_rsIHUQFPccQuJAPeggIAggBCAoQAQ\" data-complete=\"true\" data-sae=\"\">a specialized electrical safety device engineered specifically for overcurrent and short-circuit protection in photovoltaic (PV) systems, battery banks, and combiner boxes<!--TgQPHd|||[[[null,null,null,null,null,null,null,null,null,null,null,null,[247864,null,0]]]]--><\/mark>.\u00a0<!--TgQPHd|||[]--><\/div>\n<div class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgOEAA\" data-complete=\"true\" data-processed=\"true\">By containing both the fast-acting fuse link and the safe-disconnect holder in a single-pole unit, it isolates faulty solar strings to prevent thermal runaway, fire risks, and catastrophic equipment damage.\u00a0<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgREAA\" data-processed=\"true\" data-complete=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgREAI\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Rated Operating Voltage (\\(U_{e}\\)):<!--TgQPHd|||[]--><\/strong> <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">1000V DC \/ 1100V DC<!--TgQPHd|||[]--><\/strong><!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgREAQ\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Number of Poles:<!--TgQPHd|||[]--><\/strong> <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">1P (Single Pole)<!--TgQPHd|||[]--><\/strong><!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgREAU\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Standard Ampere Options:<!--TgQPHd|||[]--><\/strong> Typically available from <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">1A up to 30A \/ 32A<!--TgQPHd|||[]--><\/strong> for the standard compact housing (commonly stocked in 15A, 20A, 25A, and 32A variants).<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgREAY\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Fuse Cylinder Dimensions:<!--TgQPHd|||[]--><\/strong> Standardized <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">10&#215;38 mm<!--TgQPHd|||[]--><\/strong> cylindrical gPV fuse link.<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgREAc\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Rated Breaking Capacity:<!--TgQPHd|||[]--><\/strong> <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">30 kA<!--TgQPHd|||[]--><\/strong> at 1000Vdc, delivering high-level short-circuit limitation.<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgREAg\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Mounting Standard:<!--TgQPHd|||[]--><\/strong> <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">35mm DIN rail compatible<!--TgQPHd|||[]--><\/strong> for modular integration into distribution boards or combiner boxes.<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgREAk\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Material &amp; Safety:<!--TgQPHd|||[]--><\/strong> Enclosed in a <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">960\u00b0C flame-retardant, V0-class thermoplastic<!--TgQPHd|||[]--><\/strong> housing with an IP20 ingress protection rating.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<p><!--TgQPHd|||[]--><\/ul>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=UwQXMe_2t\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgXEAA\" data-complete=\"true\" data-sae=\"\">Suntree Solar PV DC Fuse Link with Holder 1P 1000Vdc Key Operational Features<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAA\" data-processed=\"true\" data-complete=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAI\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Fast-Acting gPV Performance:<!--TgQPHd|||[]--><\/strong> The internal pure silver melt element features a rapid <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">1\u20133ms time constant<!--TgQPHd|||[]--><\/strong>, breaking abnormal currents swiftly before they can flow back into sensitive solar panel strings.<!--TgQPHd|||[]--><\/span><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAc\" data-sae=\"\" data-complete=\"true\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Safe Disconnect under Maintenance:<!--TgQPHd|||[]--><\/strong> The holder acts as a pull-out fuse-disconnector, allowing technicians to completely isolate an individual circuit line safely. <em class=\"zhvwWe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Note: The carrier text explicitly warns: <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Do not open under load<!--TgQPHd|||[]--><\/strong>. Always turn off the DC isolator or circuit breaker before pulling the fuse.<!--TgQPHd|||[]--><\/em><!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgfEAw\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Robust Environmental Durability:<!--TgQPHd|||[]--><\/strong> Designed to operate efficiently across extreme temperatures ranging from <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">-40\u00b0C to +85\u00b0C<!--TgQPHd|||[]--><\/strong> and built to withstand prolonged corrosive\/acidic environments.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<p><!--TgQPHd|||[]--><\/ul>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=UwQXMe_4z\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgjEAA\" data-complete=\"true\" data-sae=\"\" aria-owns=\"action-menu-parent-container\">Suntree Solar PV DC Fuse Link with Holder 1P 1000Vdc Correct Sizing Rule of Thumb<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<div tabindex=\"0\" data-os-fs=\"\" aria-hidden=\"true\"><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<div class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQglEAA\" data-processed=\"true\" data-complete=\"true\">When installing these fuses on your PV inputs, the rated current of the fuse link should be sized to <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\">1.25 to 1.5 times<!--TgQPHd|||[]--><\/strong> the short-circuit current (\\(I_{sc}\\)) of your solar panel string. This buffer prevents nuisance blowing from minor daytime spikes while maintaining sharp protection against actual fault currents<\/div>\n<h2><strong>Specification<\/strong><\/h2>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"12\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">PVDC-specific(LEC 66143-1\/EN 61643-11)<\/td>\n<td colspan=\"6\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Pole<\/td>\n<td colspan=\"6\">IP<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Electrical parameter<\/td>\n<td colspan=\"6\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Rated voltage Ue(VDC)<\/td>\n<td colspan=\"6\">1000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Rated current In(A)<\/td>\n<td colspan=\"6\">20,32A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Biggest block ability(KA)<\/td>\n<td colspan=\"6\">33<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">The most high power consumption(W)<\/td>\n<td colspan=\"6\">3.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Connection and Installation<\/td>\n<td colspan=\"6\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Connerction(mm2)<\/td>\n<td colspan=\"6\">2.5\uff5e10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Working Temperature(\u2103)<\/td>\n<td colspan=\"6\">-30\uff5e+70<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Resistance and damp hot<\/td>\n<td colspan=\"6\">Class 2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Altitude(m)<\/td>\n<td colspan=\"6\">\u22642000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Relative humidity<\/td>\n<td colspan=\"6\">\u226495%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Rotection class\/degree<\/td>\n<td colspan=\"6\">IP20<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Pullotion<\/td>\n<td colspan=\"6\">3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Installation environmet<\/td>\n<td colspan=\"6\">No nbvious shock and vibration<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Installation class<\/td>\n<td colspan=\"6\">Class\u2161<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Installation type<\/td>\n<td colspan=\"6\">DIN rail<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Size\/dimension(mm)<\/td>\n<td colspan=\"6\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"3\">(W\u00d7H\u00d7L)<\/td>\n<td colspan=\"3\">W<\/td>\n<td colspan=\"6\">18<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">H<\/td>\n<td colspan=\"6\">89<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">L<\/td>\n<td colspan=\"6\">90<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Fuse size<\/td>\n<td colspan=\"6\">10\u00d738<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\">Weight(kg)<\/td>\n<td colspan=\"6\">0.07<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>The Suntree Solar PV DC Fuse Link with Holder 1P 1000Vdc\u00a0is a specialized electrical safety device engineered specifically for overcurrent and short-circuit protection in photovoltaic (PV) systems, battery banks, and combiner boxes.\u00a0 By containing both the fast-acting fuse link and the safe-disconnect holder in a single-pole unit, it isolates faulty solar strings to prevent thermal [&#8230;]\n","protected":false},"featured_media":4331,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[142],"product_cat":[94],"product_tag":[],"class_list":["post-4327","product","type-product","status-publish","has-post-thumbnail","product_brand-suntree","product_cat-dc-accessories","first","instock","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product\/4327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4327"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/media\/4331"}],"wp:attachment":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4327"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=4327"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=4327"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=4327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}