{"id":4320,"date":"2026-10-26T08:43:59","date_gmt":"2026-10-26T08:43:59","guid":{"rendered":"https:\/\/estrexsolar.co.ke\/?post_type=product&#038;p=4320"},"modified":"2026-10-31T09:04:32","modified_gmt":"2026-10-31T09:04:32","slug":"suntree-ac-surge-protector-spd-40ka-2-pole","status":"publish","type":"product","link":"https:\/\/estrexsolar.co.ke\/?product=suntree-ac-surge-protector-spd-40ka-2-pole","title":{"rendered":"Suntree AC Surge Protector (SPD) 40kA 2 Pole Single Phase"},"content":{"rendered":"<div class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgLEAA\" data-complete=\"true\" data-processed=\"true\"><span data-subtree=\"aimfl\" data-processed=\"true\">The Suntree AC Surge Protector (SPD) 40kA 2 Pole Single Phase<\/span>\u00a0is <mark class=\"b6AQX\" data-wiz-attrbind=\"class=iaOQCf_t\/cFwyDc\" data-sfc-root=\"c\" data-ved=\"2ahUKEwiHt8CJ8uOXAxV1SfEDHW5CJuwQuJAPeggIAggBCAsQAQ\" data-complete=\"true\" data-sae=\"\">a Type 2 surge protector designed to shield single-phase alternating current electrical infrastructure, sensitive electronic appliances, and solar inverter AC distribution boards from transient overvoltages<!--TgQPHd|||[[[null,null,null,null,null,null,null,null,null,null,null,null,[247864,null,0]]]]--><\/mark>. It safely diverts harmful electrical surges\u2014such as grid spikes and residual lightning impacts\u2014away from connected equipment down to the earth.\u00a0<!--TgQPHd|||[]--><\/div>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=iaOQCf_14\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgPEAA\" data-complete=\"true\" data-sae=\"\"><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=iaOQCf_14\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgPEAA\" data-complete=\"true\" data-sae=\"\">Suntree AC Surge Protector (SPD) 40kA 2 Pole Single Phase Technical Specifications<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAA\" data-complete=\"true\" data-processed=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAI\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Device Type:<!--TgQPHd|||[]--><\/strong> Type 2 AC Surge Protective Device<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAM\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Number of Poles:<!--TgQPHd|||[]--><\/strong> 2 Pole (typically protecting Live and Neutral lines)<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAQ\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">System Phase:<!--TgQPHd|||[]--><\/strong> Single-Phase<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAU\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Maximum Continuous Operating Voltage (\\(U_{c}\\)):<!--TgQPHd|||[]--><\/strong> ~275V AC (optimized for standard 220V\u2013240V AC power grids)<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAc\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Nominal Discharge Current (\\(I_{n}\\)):<!--TgQPHd|||[]--><\/strong> 20kA (8\/20\u00b5s wave profile)<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAk\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Maximum Discharge Current (\\(I_{max}\\)):<!--TgQPHd|||[]--><\/strong> 40kA (8\/20\u00b5s wave profile)<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEAs\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Voltage Protection Level (\\(U_{p}\\)):<!--TgQPHd|||[]--><\/strong> &lt; 1.8kV<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEA0\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Response Time:<!--TgQPHd|||[]--><\/strong> &lt; 20ns<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEA4\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Mounting Configuration:<!--TgQPHd|||[]--><\/strong> 35mm Standard DIN Rail<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgQEA8\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Ingress Protection Rating:<!--TgQPHd|||[]--><\/strong> IP20 (intended for indoor or enclosed panel installation)<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<p><!--TgQPHd|||[]--><\/ul>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=iaOQCf_2v\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgWEAA\" data-complete=\"true\" data-sae=\"\">Suntree AC Surge Protector (SPD) 40kA 2 Pole Single Phase Key Features<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAA\" data-complete=\"true\" data-processed=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAI\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Modular Pluggable Core:<!--TgQPHd|||[]--><\/strong> The device relies on a two-body design. If a massive electrical surge degrades the protective module, you can pull it out and snap in a replacement module without needing to rewire the entire base or power down the whole consumer unit.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAc\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Visual Status Indicators:<!--TgQPHd|||[]--><\/strong> Features mechanical color-coded flag windows on the front face of each module. <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Green<!--TgQPHd|||[]--><\/strong> indicates the device is operating properly; <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Red<!--TgQPHd|||[]--><\/strong> indicates the internal thermal\/overcurrent tripping has triggered and the module must be replaced immediately.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAw\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Flame Retardant Design:<!--TgQPHd|||[]--><\/strong> Constructed using high-grade thermoplastic materials (PBT\/PA66) that comply with UL94 V-0 anti-flaming industrial standards.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<p><!--TgQPHd|||[]--><\/ul>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=iaOQCf_53\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgiEAA\" data-complete=\"true\" data-sae=\"\">Important Installation Context<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgkEAA\" data-complete=\"true\" data-processed=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgkEAI\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Earthing Requirement:<!--TgQPHd|||[]--><\/strong> A surge protector cannot function without a dedicated grounding wire. The excess electrical charge requires a short, thick grounding pathway to the earth bar to effectively clear surges.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgkEAg\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Upstream Protection:<!--TgQPHd|||[]--><\/strong> It must always be installed in parallel with your system and placed downstream of a dedicated backup overcurrent device\u2014such as a 16A to 32A miniature circuit breaker (MCB) or fuse\u2014to prevent continuous fault currents in the event of an SPD failure.<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The Suntree AC Surge Protector (SPD) 40kA 2 Pole Single Phase\u00a0is a Type 2 surge protector designed to shield single-phase alternating current electrical infrastructure, sensitive electronic appliances, and solar inverter AC distribution boards from transient overvoltages. It safely diverts harmful electrical surges\u2014such as grid spikes and residual lightning impacts\u2014away from connected equipment down to the [&#8230;]\n","protected":false},"featured_media":4321,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[142],"product_cat":[118],"product_tag":[],"class_list":["post-4320","product","type-product","status-publish","has-post-thumbnail","product_brand-suntree","product_cat-spd","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product\/4320","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4320"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/media\/4321"}],"wp:attachment":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4320"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=4320"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=4320"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=4320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}