{"id":4315,"date":"2026-10-24T12:56:54","date_gmt":"2026-10-24T12:56:54","guid":{"rendered":"https:\/\/estrexsolar.co.ke\/?post_type=product&#038;p=4315"},"modified":"2026-10-31T09:34:53","modified_gmt":"2026-10-31T09:34:53","slug":"suntree-solar-dc-surge-protector-spd-40ka-3-pole-1000vdc","status":"publish","type":"product","link":"https:\/\/estrexsolar.co.ke\/?product=suntree-solar-dc-surge-protector-spd-40ka-3-pole-1000vdc","title":{"rendered":"Suntree Solar DC Surge Protector (SPD) 40kA 3 Pole 1000Vdc"},"content":{"rendered":"<div class=\"n6owBd awi2gc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgKEAA\" data-complete=\"true\" data-processed=\"true\"><span data-subtree=\"aimfl\" data-processed=\"true\">The Suntree Solar DC Surge Protector (SPD) 40kA 3 Pole 1000Vdc<\/span>\u00a0is <mark class=\"b6AQX\" data-wiz-attrbind=\"class=r8Pvec_t\/cFwyDc\" data-sfc-root=\"c\" data-ved=\"2ahUKEwiU6crL-eOXAxXchP0HHQ42PdEQuJAPeggIAggBCAoQAQ\" data-complete=\"true\" data-sae=\"\">a critical safety component designed to protect solar photovoltaic (PV) inverters, batteries, and panels from transient voltage surges and lightning strikes<!--TgQPHd|||[[[null,null,null,null,null,null,null,null,null,null,null,null,[247864,null,0]]]]--><\/mark>. By creating a safe, low-impedance path to ground, it diverts harmful excess energy before it can destroy sensitive equipment.<!--TgQPHd|||[]--><\/div>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=r8Pvec_18\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAA\" data-complete=\"true\" data-sae=\"\"><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=r8Pvec_18\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgSEAA\" data-complete=\"true\" data-sae=\"\">Suntree Solar DC Surge Protector (SPD) 40kA 3 Pole 1000Vdc Technical Specifications<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAA\" data-complete=\"true\" data-processed=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAI\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Product Model:<!--TgQPHd|||[]--><\/strong> SUP2H1-PV<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAM\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Number of Poles:<!--TgQPHd|||[]--><\/strong> 3-Pole (3P) for comprehensive positive, negative, and ground line protection<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAQ\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Max. Continuous Operating Voltage (\\(U_{c}\\)):<!--TgQPHd|||[]--><\/strong> 1000V DC<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAY\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Max. Discharge Current (\\(I_{max}\\)):<!--TgQPHd|||[]--><\/strong> 40kA (using an 8\/20 \u03bcs waveform)<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAg\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Nominal Discharge Current (\\(I_{n}\\)):<!--TgQPHd|||[]--><\/strong> 20kA<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAo\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Voltage Protection Level (\\(U_{p}\\)):<!--TgQPHd|||[]--><\/strong> 3.6 kV<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEAw\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Response Time:<!--TgQPHd|||[]--><\/strong> &lt; 25 ns<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEA0\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Installation Mode:<!--TgQPHd|||[]--><\/strong> 35mm standard DIN rail mount<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEA4\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Ingress Protection:<!--TgQPHd|||[]--><\/strong> IP20<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgYEA8\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Certifications:<!--TgQPHd|||[]--><\/strong> CE, T\u00dcV Rheinland, and IEC 61643-31 compliant<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<p><!--TgQPHd|||[]--><\/ul>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=r8Pvec_3v\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgcEAA\" data-complete=\"true\" data-sae=\"\">Core Features &amp; Architecture<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAA\" data-processed=\"true\" data-complete=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAI\" data-complete=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Modular Plug-In Design:<!--TgQPHd|||[]--><\/strong> The internal protective components utilize plug-in clips, making it easy to swap out degraded modules without rewiring the base.<!--TgQPHd|||[]--><\/span>\u00a0<!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEAc\" data-sae=\"\" data-complete=\"true\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Visual Status Indicators:<!--TgQPHd|||[]--><\/strong> It features clear inspection windows. A <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Green<!--TgQPHd|||[]--><\/strong> window indicates normal operation, while a <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Red<!--TgQPHd|||[]--><\/strong> window warns that the module has failed and must be replaced.<\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgeEA0\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Integrated Safety Mechanisms:<!--TgQPHd|||[]--><\/strong> Equipped with an internal flash barrier to stop arc propagation and a combined disconnection\/short-circuiting device to eliminate fire hazards from DC arcs.<\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<p><!--TgQPHd|||[]--><\/ul>\n<div class=\"yhAwj\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" data-processed=\"true\" data-sfc-inited=\"2\"><!--TgQPHd|||[]--><\/div>\n<div class=\"ZLzG0d ncoeY E8xBUb\" role=\"heading\" aria-level=\"3\" data-animation-nesting=\"\" data-sfc-cp=\"\" data-wiz-attrbind=\"aria-level=r8Pvec_52\/fLk2Md\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgiEAA\" data-complete=\"true\" data-sae=\"\">Installation Best Practices<!--TgQPHd|||[[2,[null,null,1,null,null,null,null,null,null,null,null,null,[351768,null,0]],null,null,1]]--><\/div>\n<p><!--TgQPHd|||[]--><\/p>\n<ul class=\"XSq4R KI3fJ\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgjEAA\" data-processed=\"true\" data-complete=\"true\">\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgjEAI\" data-sae=\"\" data-complete=\"true\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Voltage Cushion:<!--TgQPHd|||[]--><\/strong> For safety and long-term system stability, ensure that the open-circuit voltage (\\(U_{oc}\\)) of your solar string does not exceed roughly <strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">830V DC<!--TgQPHd|||[]--><\/strong> (allowing the recommended 1.2\u00d7 safety factor below the SPD&#8217;s 1000V limit).<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgjEAQ\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Placement:<!--TgQPHd|||[]--><\/strong> It should be installed in a DC combiner box or a distribution enclosure between the solar panel array and the inverter.<!--TgQPHd|||[]--><\/span><!--TgQPHd|||[]--><!--TgQPHd|||[]--><\/li>\n<li class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-hveid=\"CAIIAQgjEAU\" data-complete=\"true\" data-processed=\"true\" data-sae=\"\"><span class=\"iNqyIf\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\" aria-owns=\"action-menu-parent-container\"><strong class=\"rQesXe MPyX\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-complete=\"true\">Safe Distances:<!--TgQPHd|||[]--><\/strong> Maintain at least a 10mm safety gap between the SPD module and any other grounded components inside the housing.<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The Suntree Solar DC Surge Protector (SPD) 40kA 3 Pole 1000Vdc\u00a0is a critical safety component designed to protect solar photovoltaic (PV) inverters, batteries, and panels from transient voltage surges and lightning strikes. By creating a safe, low-impedance path to ground, it diverts harmful excess energy before it can destroy sensitive equipment. Suntree Solar DC Surge [&#8230;]\n","protected":false},"featured_media":4316,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[142],"product_cat":[94],"product_tag":[],"class_list":["post-4315","product","type-product","status-publish","has-post-thumbnail","product_brand-suntree","product_cat-dc-accessories","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product\/4315","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4315"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=\/wp\/v2\/media\/4316"}],"wp:attachment":[{"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4315"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=4315"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=4315"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/estrexsolar.co.ke\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=4315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}